Each pixel sees 0.987 mm of surface per metre of distance.

What do you need to do with the defect?

Facade pass

Max standoff– m
Thermal pixel size at your standoff– cm/px
Result–

Roof pass

Max height above roof– m
Thermal pixel size at your height– cm/px
Result–

How the distances are worked out

Each thermal pixel sees about 1 mm of surface for every metre of distance (0.99 mm per metre for the camera set above). At 10 m, one pixel covers about 1 cm. To get enough pixels across a defect, the camera has to be close enough that the defect is several pixels wide.

Diagram: a camera at point A is 10 m up and 10 m across from a defect at point B. The straight-line distance between them is 14.1 m, not 10 m.
Max distance = defect size ÷ (pixels across × 0.99 mm per metre)
–
  1. –
  2. –

Each defect under each scenario, as straight-line distance from the camera:

You need toPixels acrossFacade: max distance to a 50 mm defectRoof: max distance to a 70 mm defect
Measure its temperature3––
See its shape and edges5––

Once the camera is far enough that the defect is smaller than one pixel, its heat gets averaged in with the surface around it and it won't reliably show up at all. That's why there's no 1-pixel option.

Based on the camera set above (640 × 512, 35.05° horizontal field of view), where each pixel sees 0.987 mm per metre, looking straight at the surface. Oblique angles, wind and image blur make the usable distance shorter. A planning guide only.